The electromagnetic flowmeters PFLOQUA are measuring devices designed to measure the flow of electrically-conductive liquids with a conductivity greater than 5 μS/cm in closed pipeline installations.
PFLOQUA electromagnetic flow meters are used in water and wastewater management, heat-supply systems and in many industries, eg. chemical and food industries. Measure the pure and contaminated liquids, sludge, pulp and aggressive liquids.
| Parameter | Optional manufacture of converter | |||
| Converter | PFLOQUA FL110 | PFLOQUA FL210 | PFLOQUA FL145 | PFLOQUA FL255 |
| Version | Separate | |||
| Casing material/Protection class | - | Stainless steel type AISI 304/IP67 or IP68 | ||
| Power Supply | 18-45 V DC/AC (6W-7VA) | 18-45 V AC (25 VA) 44-66 Hz 18-45 V DC (20 W) 10-35 V DC (20 W) | up to 6 non-rechargeable lithium type D batteries + power supply: 10-30V DC | up to 6 lithium type D batteries |
| Output: pulse / alarm | - | 2 outputs with parameters: 1250 Hz, 100 mA, 40 V DC (optionally: 12.5 kHz): converter | 2 outputs with parameters: 50 Hz, 100 mA, 40 V DC | |
| Current outputs | 0/4-20 mA - RL = 800 Ω | 0/4-20 mA - RL = 1000 Ω (+1 optional) | 0/4-20 mA (available only with power adapter) | - |
| Digital input | - | 1 input on / off | ||
| Communication port | RS485 | RS485 RS232 | - | RS232 (protocols DPP / HTP) |
| Communication protocol | MODBUS RTU | MODBUS RTU; Profibus DP; HART | - | DPP / HTP |
| BlueTooth interface | - | yes | - | - |
| Module GSM / GPRS (SMS / CSD) | - | - | - | yes |
| Additional measurements | - | - | - | ability to connect two pressure sensors or a temperature sensor |
| Flow sensor | Optional sensor FL1000 / FL2500 | |||
| Material of the body and flanges | stainless steel AISI 304 or AISI 316 | |||
| Nominal pressure | PN10, PN25, PN40, PN64 | |||
| Lining type | PTFE, rilsan | |||
| Connection for FL2500 | Flanges acc. to ANSI, DIN, JIS and other | |||
| Temperature of liquid | 0 + 70ºC (rilsan lining) -20 ÷ 100ºC (PTFE lining / compact version) -20 ÷ 150ºC (PTFE lining / separete version) -20 ÷ 180ºC (PTFE lining / separete version) |
|||
| Electrode material | Hastelloy C, titanium, tantalum, platinum, other | |||
| Protection class | IP58 | |||
| CODE | DN [mm] | Qmin [m3/h] | Qmax [m3/h] | Electromagnectic flow meters |
| PFLOQUA FL* | 25 | 0,72 | 18 |
| 32 | 1,16 | 29 | |
| 40 | 1,8 | 45 | |
| 50 | 2,88 | 72 | |
| 65 | 4,8 | 120 | |
| 80 | 7,2 | 180 | |
| 100 | 11,2 | 280 | |
| 125 | 18 | 450 | |
| 150 | 25,6 | 640 | |
| 200 | 45,2 | 1130 | |
| 250 | 70,8 | 1770 | |
| 300 | 100,8 | 2520 | |
| 350 | 138 | 3450 | |
| 400 | 180 | 4500 | |
| 450 | 228,8 | 5720 | |
| 500 | 284 | 7100 | |
| 600 | 408 | 10200 | |
| 700 | 560 | 14000 | |
| 800 | 720 | 18000 | |
| 900 | 920 | 23000 | |
| 1000 | 1140 | 28500 | |
| 1200 | 1600 | 40000 | |
| 1400 | 2200 | 55000 | |
| 1600 | 2880 | 72000 | |
| 1800 | 3640 | 91000 | |
| 2000 | 4520 | 113000 |
* Standard design: -PN16