The electromagnetic flowmeters PFLOQUA are measuring devices designed to measure the flow of electrically-conductive liquids with a conductivity greater than 5 μS/cm in closed pipeline installations.
PFLOQUA electromagnetic flow meters are used in water and wastewater management, heat-supply systems and in many industries, eg. chemical and food industries. Measure the pure and contaminated liquids, sludge, pulp and aggressive liquids.
Parameter | Optional manufacture of converter | |||
Converter | PFLOQUA FL110 | PFLOQUA FL210 | PFLOQUA FL145 | PFLOQUA FL255 |
Version | Separate | |||
Casing material/Protection class | - | Stainless steel type AISI 304/IP67 or IP68 | ||
Power Supply | 18-45 V DC/AC (6W-7VA) | 18-45 V AC (25 VA) 44-66 Hz 18-45 V DC (20 W) 10-35 V DC (20 W) | up to 6 non-rechargeable lithium type D batteries + power supply: 10-30V DC | up to 6 lithium type D batteries |
Output: pulse / alarm | - | 2 outputs with parameters: 1250 Hz, 100 mA, 40 V DC (optionally: 12.5 kHz): converter | 2 outputs with parameters: 50 Hz, 100 mA, 40 V DC | |
Current outputs | 0/4-20 mA - RL = 800 Ω | 0/4-20 mA - RL = 1000 Ω (+1 optional) | 0/4-20 mA (available only with power adapter) | - |
Digital input | - | 1 input on / off | ||
Communication port | RS485 | RS485 RS232 | - | RS232 (protocols DPP / HTP) |
Communication protocol | MODBUS RTU | MODBUS RTU; Profibus DP; HART | - | DPP / HTP |
BlueTooth interface | - | yes | - | - |
Module GSM / GPRS (SMS / CSD) | - | - | - | yes |
Additional measurements | - | - | - | ability to connect two pressure sensors or a temperature sensor |
Flow sensor | Optional sensor FL1000 / FL2500 | |||
Material of the body and flanges | stainless steel AISI 304 or AISI 316 | |||
Nominal pressure | PN10, PN25, PN40, PN64 | |||
Lining type | PTFE, rilsan | |||
Connection for FL2500 | Flanges acc. to ANSI, DIN, JIS and other | |||
Temperature of liquid | 0 + 70ºC (rilsan lining) -20 ÷ 100ºC (PTFE lining / compact version) -20 ÷ 150ºC (PTFE lining / separete version) -20 ÷ 180ºC (PTFE lining / separete version) |
|||
Electrode material | Hastelloy C, titanium, tantalum, platinum, other | |||
Protection class | IP58 |
CODE | DN [mm] | Qmin [m3/h] | Qmax [m3/h] | Electromagnectic flow meters |
PFLOQUA FL* | 25 | 0,72 | 18 |
32 | 1,16 | 29 | |
40 | 1,8 | 45 | |
50 | 2,88 | 72 | |
65 | 4,8 | 120 | |
80 | 7,2 | 180 | |
100 | 11,2 | 280 | |
125 | 18 | 450 | |
150 | 25,6 | 640 | |
200 | 45,2 | 1130 | |
250 | 70,8 | 1770 | |
300 | 100,8 | 2520 | |
350 | 138 | 3450 | |
400 | 180 | 4500 | |
450 | 228,8 | 5720 | |
500 | 284 | 7100 | |
600 | 408 | 10200 | |
700 | 560 | 14000 | |
800 | 720 | 18000 | |
900 | 920 | 23000 | |
1000 | 1140 | 28500 | |
1200 | 1600 | 40000 | |
1400 | 2200 | 55000 | |
1600 | 2880 | 72000 | |
1800 | 3640 | 91000 | |
2000 | 4520 | 113000 |
* Standard design: -PN16